Checking at malfunctions ÀÒC
Here the description of checks which are necessary to perform at failure detection of the controller or the gauge is resulted, the table allowing correctly to classify malfunction is resulted, that in turn will facilitate elimination of the arisen malfunction.
Basic check at malfunction of the controller
At malfunction of the controller on the index of temperature there is an inscription of malfunction, target and suction apertures accordingly are fixed on the mode to the bottom / glass and external air, and air mixing flap - in position at the moment of occurrence of malfunctions.
If after indication of malfunction on the index of temperature even at check there is no code of malfunction it means malfunction of the controller.
|
À1 – relay (high speed of blowing) À2 – vacuum switching valve (air stream to the glass) A3 – grounding of feeding À5 – engine of air mixing flap À6 – basic feeding À7 – vacuum switching valve À9 – switch of headlights light (+) À10 – grounding of gauges All – engine of air mixing flap (grounding) À12, À13, À14 – air-conditioner relay |
B1 – vacuum switching valve (air stream to the floor) B2 – relay (low speed of blowing) B3 – vacuum switching valve (ventilation) B5 – vacuum valve (ventilation 2) B6 – relay (second speed of blowing) B7 – relay (third speed of blowing) B9 – engine of air mixing flap (MTR +) B10 – engine of air mixing flap (MTR–) B11 – gauge of temperature in the interior B12 – gauge of external air temperature B13 – gauge of moisture B14 – solar gauge B15 – engine of air mixing flap (+VS) B16 – switch (–) |
Basic checking of each gauge
Before carrying out of checking concerning each gauge, first of all, they define the presence of malfunction or breakage of the circuit of each gauge with the help of the self-diagnostics function additionally stipulated by the controller.
Checking of the gauge based on using of self-diagnostics function
At occurrence of malfunctions in the gauge system at input of signals during the operating time of ATC, index of the controller temperature shows malfunction (automatic mode status).
At simultaneous pressing of switches of temperature adjustment, there appears the designation of a code of malfunction (if the designation of a code of malfunction does not appear, the controller is faulty).
On the code of malfunction it is possible to define malfunction of the gauge.
Code of malfunction |
Content |
001 |
Malfunction (air thermode) in the interior |
002 |
Malfunction of external air thermode |
003 |
Malfunction of water thermode |
004 |
Malfunction of pot resistor of air mixing flap |
005 |
Malfunction of solar gauge |
|
At simultaneous malfunction of more than two gauges, consistently, with an interval in 1 second, there appears designation of the code of malfunction.
|