Maintenance service of the bench equipment
Attention: oil in the pump should be replaced quarterly.
- To start the power switch.
- To turn the manual gates located on both ends of the hose.
- To press button RECLAIM ONLY.
- At ignition of green lamp LED it is necessary to disconnect MRC device from the power supply (switching-off of the electric power).
- To unscrew two screws located below on the front side of the control panel and to raise the control panel.
Attention: At the following stage there may be the refrigerant under pressure. Therefore it is necessary to dress goggles and gloves
- After having marked the entrance, target and returnable hoses for simplification of posting at return installation, to remove these hoses.
- After having turned out under the shelf fixing nuts, to remove the oil cylinder.
- After having inclined the tank, to fill oil according to the rules in capacity.
- Using a small funnel, to fill the pump oil into the exhaust outlet PORT of an oil tank.
- To set up again oil tank on a shelf located in a cell, to fix with earlier turned off nuts.
- To connect again 3 hoses to each aperture.
- To close the control panel and to tighten screws.
Way of storage of MRC-450 device on long term
|
1 – oil tank 2 – pump 3 – screws |
|
At storage of MRC on long term and for maintenance of the appropriate characteristics it is necessary:
- Performance of consecutive maintenance service of suction separator.
- Using the sequence of maintenance service of the pump, to replace the pump oil.
- To close all manual gates which are placed on the recycling tank, filling tank, hoses.
|