Maintenance service of the bench equipment

Attention: Fulfilled main filter may contain a liquid refrigerant. According to the following order it is necessary to remove the refrigerant slowly.

  • To close both gates above the hoses.
  • To choose a mode only for return on regeneration (RECLAIM ONLY), located on the control panel.
  • To remove from the hose the refrigerant before ignition of a green lamp of "termination("ending") (COMPLETED LED).
  • After having disconnected the dark blue hose from LOW PORT cells, to connect there the yellow hose.
  • To connect the other end of the yellow hose to the exhaust outlet of fitting of the fulfilled main filter.
  • To choose a mode on the control panel only for return on regeneration (RECLAIM ONLY).
  • From the fulfilled main filter to remove the refrigerant before ignition of a green lamp of "termination("ending") (COMPLATED LED).