Diagnosing of malfunctions

Reference table for diagnosing malfunctions

This table is used, when because of any defect function of self-diagnosing does not work. Depending on a kind of defect under the table resulted below, under the order, the system is checked.

Defect type System
Wind blower
electric motor
Power transistor Internal, external air
adjustment electric motor
MODE CONTROL
electric motor
AIR MLX CONTROL
electric motor
Thermode behind evaporator External air thermode Internal air thermode Automatic
regulator unit
Automatic thermoregulator does not move at all                 1
At “ON” ignition switching-off, the fan electric motor rotates with high speed at any position of the fan switch.   1             2
Fan electric motor does not work at all 1               2
Fan electric motor rotates only in the position of maximum speed, but in all the others - no   1             2
Function of external air cut does not work     1           2
Mode control does not work       1         2
Cold air does not go out of the fan           3 2 1  
Hot air does not go out of the fan         1   3 2  
Saloon temperature differs from the chosen temperature           1 1 3 2

 

Defect type System
Fan
electric motor
Radiator fan control mode Air-conditioner pressure system Triple switch-off of the air-conditioner pressure Fan control unit Automatic
thermoregulator
unit
Radiator and condenser fans do not work         1 2
Radiator and condenser fans do not work at all. 1 2     3  
Radiator and condenser fans do not rotate with high speed     1 2 3  
Radiator and condenser fans do not rotate with low speed   1 2 3 4  
Compressor bushing does not work     1 2 3 4